Basic Info.
Model NO. | AG700 | Power Source | USB Type-Micro |
Trademark | OEM/ODM | Origin | Kunshan,China |
Sensor Type | Dual-Beam NDIR | HS Code | 9027100090 |
CO2 Range | 0~5000ppm | Production Capacity | 80000 Pieces/Year |
Temperature Range | 0~50ºC(32°F to 122°F) | Transport Package | Carton |
RH Range | 0-100% | Package Type | 1 pcs/Color Box |
Battery | External | Weight | 148g Device only |
Single Package Size | 120*91.2*27mm (4.7*3.6*1.1inch) |
|
|
Product Description:
AG700 is a 3 in 1 Desktop CO2 Monitor measures the indoor air quality index, including the CO2, TEMP, and RH. By using Dual Beam NDIR technology, it provide accurate CO2 readings ranging from 0 to 5000 ppm. It has Human and plant modes built in.
In human mode, it is useful in verifying indoor air quality for home, office, school,restaurant, library, station, or vehicle interior.
In plant mode, it is a guardian for users to control CO2 level in greenhouses or hydroponics to achieve the goal of efficient plant growth and increase yield.
Feature:
Ø Dual Beam NDIR (Non-Dispersive-Infrared) technology is used to improvethe long term stability.
Ø CO2/Temperature/RH Monitor; Tracer
Ø Chart with variable time Zoom Levels
Ø Build-In Plant Types Directory
Ø 3-color LED (green / yellow / red) gradually changes color with CO2 concentration.
Ø Foolproof “Hold Home” function.
Ø CRR, CO2 Replenish Reminder.
Specifications:
Typical test conditions, unless otherwise specified: Ambient Temp =23+/-3°C, RH=50%-70%, Altitude=0~100 meter
Measurement | Specifications |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating & Storage RH | 0-95%, non-condensing |
CO2 Measurement |
|
Accuracy at 0~3000ppm | ±50ppm or ±5% of reading, whichever is greater |
Accuracy over 3000ppm | ±7% |
Repeatability | 20ppm at 400ppm (standard dev. of 10 readings in 1 minute) |
Measurement Range | 0-5000ppm |
Display Resolution | 1ppm (0-1000); 5ppm(1000-2000); 10ppm (>2000) |
Temp Dependence | ±0.1% of reading per°C or ±2ppm per °C, whichever is greater, referenced to 25°C |
Pressure Dependence | 0.13% of reading per mmHg (corrected by user’s altitude input) |
Response Time | <2min for 63% ofstep change or <4.6min for 90% step change |
Warm-up Time | <30 sec |
Temp Measurement |
|
Operating Temperature | 32°F to 122°F (0°C-50°C) |
Display Resolution | 0.2°F (0.1°C) |
Accuracy | ±1°F (±0.5°C) |
Response Time | <20min (63%) |
RH Measurement |
|
Range | 0-100% |
Accuracy | ±5% |
Resolution | 1% on MainReading, 0.1% on Max Min Reading |
|
|
Power Requirements | 160mA Peak, 15mAaverage at 5.0V |
Battery Life | Battery is not included. below is calculation by theory: (reference only, not a guarantee) For 5000mAh battery, 200Hr/8.3day |
|
|